Boonton 4500B Peak Power Meter Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Boonton 4500B Peak Power Meter. Boonton 4500B Peak Power Meter User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 372
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1

Wireless Telecom Group 25 EASTMANS ROAD, PARSIPPANY, NJ 07054 Telephone: 973-386-9696 Fax: 973-386-9191 Email: [email protected] Web: www

Página 2

Boonton 4500B RF Peak Power Analyzer Contents x DISPlay:PARAmeter:MIDdle:MIDdle... 5-24 DIS

Página 3 - SAFETY SUMMARY

Boonton 4500B RF Peak Power Analyzer Operation 4-28 Table 4-6. Chan Math > Expression > Submenu (continued) Menu Item Function

Página 4

Boonton 4500B RF Peak Power Analyzer Operation 4-29 Stored Traces Select Chan Mem # > Selection > Mem 1 or Chan Mem # > Selection > Me

Página 5

Boonton 4500B RF Peak Power Analyzer Operation 4-30 Table 4-7. Chan Mem # > Menu Menu Item Function (Type) Selections

Página 6

Boonton 4500B RF Peak Power Analyzer Operation 4-31 Table 4-7. Chan Mem # > Menu (continued) Menu Item Function (Type) Sel

Página 7

Boonton 4500B RF Peak Power Analyzer Operation 4-32 External Trigger Channels The external trigger channels, one for each installed measurement chann

Página 8

Boonton 4500B RF Peak Power Analyzer Operation 4-33 Table 4-7B. Ext Trig # > Menu (continued) Menu Item Function (Type) Se

Página 9

Boonton 4500B RF Peak Power Analyzer Operation 4-34 Table 4-7C. Ext Trig # > Calibration > Submenu Menu Item Function (Type)

Página 10 - Contents

Boonton 4500B RF Peak Power Analyzer Operation 4-35 Table 4-7D. Ext Trig # > Extensions > Submenu Menu Item Function (Type)

Página 11

Boonton 4500B RF Peak Power Analyzer Operation 4-36 Table 4-7D. Ext Trig # > Extensions > Submenu (continued) Menu Item Functio

Página 12

Boonton 4500B RF Peak Power Analyzer Operation 4-37 4.10 TIME (STAT) Key and Time > Menu In the Pulse & Mod modes the TIME key activates the T

Página 13

Boonton 4500B RF Peak Power Analyzer Contents xi FETCh:MARKer:DELTa? ...

Página 14

Boonton 4500B RF Peak Power Analyzer Operation 4-38 Table 4-8A. Time > Menu (continued) Menu Item Function (Type) Select

Página 15

Boonton 4500B RF Peak Power Analyzer Operation 4-39 Table 4-8B. Statistics > Menu Menu Item Function (Type) Selections (

Página 16

Boonton 4500B RF Peak Power Analyzer Operation 4-40 Table 4-8B. Statistics > Menu (continued) Menu Item Function (Type) Selec

Página 17 - 1. General Information

Boonton 4500B RF Peak Power Analyzer Operation 4-41 Table 4-8B. Statistics > Menu (continued) Menu Item Function (Type) Selec

Página 18 - 1.2 Description

Boonton 4500B RF Peak Power Analyzer Operation 4-42 Table 4-8C. Statistics > Term Settings > Submenu Menu Item (Type) Selections

Página 19

Boonton 4500B RF Peak Power Analyzer Operation 4-43 4.11 TRIG Key and Trig > Menu The TRIG key activates the Trig > menu (Figure 4-27), which

Página 20

Boonton 4500B RF Peak Power Analyzer Operation 4-44 Table 4-9. Trig > Menu (continued) Menu Item Function (Type) Selectio

Página 21 - 1.4 Accessories

Boonton 4500B RF Peak Power Analyzer Operation 4-45 Table 4-9. Trig > Menu (continued) Menu Item Function (Type) Selections

Página 22 - 1.6 Specifications

Boonton 4500B RF Peak Power Analyzer Operation 4-46 Table 4-9. Trig > Menu (continued) Menu Item Function (Type) Selections

Página 23

Boonton 4500B RF Peak Power Analyzer Operation 4-47 Table 4-9. Trig > Menu (continued) Menu Item Function (Type) Selections

Página 24

Boonton 4500B RF Peak Power Analyzer Contents xii OUTPut:LEVel:STEP ...

Página 25

Boonton 4500B RF Peak Power Analyzer Operation 4-48 Table 4-9A. Trig > B Trig > Submenu (continued) Menu Item Function (Typ

Página 26

Boonton 4500B RF Peak Power Analyzer Operation 4-49 Table 4-9B. Trig > Menu (modulated) Menu Item (Type) Selections Function Tr

Página 27

Boonton 4500B RF Peak Power Analyzer Operation 4-50 Table 4-9C. Trig > Menu (statistical) Menu Item (Type) Selections Function

Página 28

Boonton 4500B RF Peak Power Analyzer Operation 4-51 Table 4-9C. Trig > Menu (statistical) (continued) Menu Item (Type) Selections

Página 29 - 2. Installation

Boonton 4500B RF Peak Power Analyzer Operation 4-52 Procedure To make time interval measurements, position Time Marks 1 and 2 at the beginning and e

Página 30 - 2.3 Connections

Boonton 4500B RF Peak Power Analyzer Operation 4-53 Table 4-11. Mark > Menu (continued) Menu Item Function (Type) Selections

Página 31 - 2.4 Preliminary Check

Boonton 4500B RF Peak Power Analyzer Operation 4-54 Table 4-12. Mark > Extensions > Submenu Menu Item Function (Type)

Página 32

Boonton 4500B RF Peak Power Analyzer Operation 4-55 Table 4-12. Mark > Extensions > Submenu (continued) Menu Item Function

Página 33

Boonton 4500B RF Peak Power Analyzer Operation 4-56 Table 4-12. Mark > Extensions > Submenu (continued) Menu Item (Type) Selections

Página 34

Boonton 4500B RF Peak Power Analyzer Operation 4-57 Table 4-12. Mark > Extensions > Submenu (continued) Menu Item Fu

Página 35 - 3. Getting Started

Boonton 4500B RF Peak Power Analyzer Contents xiii SENSe:CORRection:TEMPcomp... 5-6

Página 36 - Getting Started

Boonton 4500B RF Peak Power Analyzer Operation 4-58 Fig. 29c. Characteristics of the Peak-to-Average Ratio meas

Página 37

Boonton 4500B RF Peak Power Analyzer Operation 4-59 4.13 REF Key and Ref > Menu The REF function key activates the Ref > menu, which controls t

Página 38

Boonton 4500B RF Peak Power Analyzer Operation 4-60 Table 4-13. Ref > Menu (continued) Menu Item Function (Type) Selections

Página 39

Boonton 4500B RF Peak Power Analyzer Operation 4-61 4.14 MEAS Key and Meas > Menu The MEAS function key activates the Meas > menu (Figure 4-32)

Página 40

Boonton 4500B RF Peak Power Analyzer Operation 4-62 Table 4-15. Meas > Menu (pulse and modulated) (continued) Menu Item Function

Página 41

Boonton 4500B RF Peak Power Analyzer Operation 4-63 Table 4-15A. Meas > Auto Meas Menu (pulse) (continued) Menu Item Function (Ty

Página 42

Boonton 4500B RF Peak Power Analyzer Operation 4-64 Table 4-15B. Meas > Auto Meas > Skew > Submenu (pulse) Menu Item Functio

Página 43 - 3.3 LCD Monitor Display

Boonton 4500B RF Peak Power Analyzer Operation 4-65 Table 4-16. Meas > Param Meas > Submenu (pulse) Menu Item Function (Type)

Página 44

Boonton 4500B RF Peak Power Analyzer Operation 4-66 Table 4-16A. DISPLAY PARAMETER TABLE NUMBER PARAMETER DESCRIPTION 1 Pulse Width

Página 45

Boonton 4500B RF Peak Power Analyzer Operation 4-67 Table 4-17. Meas > Menu (Statistical) Menu Item Function (Type) Selection

Página 46 - 3.4 Initialize

Boonton 4500B RF Peak Power Analyzer Contents xiv SYSTem:PRESet ...

Página 47

Boonton 4500B RF Peak Power Analyzer Operation 4-68 4.15 UTIL Key and Util > Menu The UTIL key activates the Util > menu (See Table 4-20 and Fi

Página 48 - Top Level Menu

Boonton 4500B RF Peak Power Analyzer Operation 4-69 Table 4-19. Util > Remote Conf > Submenu Menu Item (Type) Selections Func

Página 49

Boonton 4500B RF Peak Power Analyzer Operation 4-70 Table 4-20. Util > Remote Conf > GPIB > Submenu Menu Item Function (T

Página 50

Boonton 4500B RF Peak Power Analyzer Operation 4-71 Table 4-20. Util > Remote Conf > GPIB > Submenu (continued) Menu Item (Type) S

Página 51

Boonton 4500B RF Peak Power Analyzer Operation 4-72 Table 4-21. Util > Remote Conf > GPIB > Setup > Submenu Menu Item Funct

Página 52 - STEP PROCEDURE

Boonton 4500B RF Peak Power Analyzer Operation 4-73 Table 4-21. Util > Remote Conf > GPIB > Setup > Submenu (continued) Menu Item

Página 53

Boonton 4500B RF Peak Power Analyzer Operation 4-74 Table 4-21A. Util > Remote > LAN Config > Submenu (Opt 11 only) Menu Item

Página 54

Boonton 4500B RF Peak Power Analyzer Operation 4-75 Table 4-22. Util > Remote Conf > Emulation > Submenu Menu Item Function (

Página 55

Boonton 4500B RF Peak Power Analyzer Operation 4-76 Table 4-23. Util > Disk (1 of 2) > Submenu Menu Item (Type) Selections Fu

Página 56

Boonton 4500B RF Peak Power Analyzer Operation 4-77 Table 4-24. Util > Disk (1 of 2) > Rename > Submenu Menu Item (Type) Selection

Página 57

Boonton 4500B RF Peak Power Analyzer Contents xv Automatic Measurement Criteria ...

Página 58

Boonton 4500B RF Peak Power Analyzer Operation 4-78 Table 4-26. Util > Disk (2 of 2) > Submenu Menu Item (Type) Selections Fu

Página 59

Boonton 4500B RF Peak Power Analyzer Operation 4-79 Table 4-27. Util > Disk (2 of 2) > Folder > Submenu Menu Item (Type) Selectio

Página 60

Boonton 4500B RF Peak Power Analyzer Operation 4-80 Table 4-28. Util > Disk (2 of 2) > Folder > Create > Submenu Menu Item (Type)

Página 61

Boonton 4500B RF Peak Power Analyzer Operation 4-81 Table 4-29. Util > Hardcopy > Submenu Menu Item Function (Type) Sel

Página 62

Boonton 4500B RF Peak Power Analyzer Operation 4-82 Table 4-30. Util > Clock > Menu Menu Item Function (Type) Selection

Página 63

Boonton 4500B RF Peak Power Analyzer Operation 4-83 4.16 CAL Key and Calibrator > Menu With the Calibrator > menu (Figure 4-45), you can turn o

Página 64

Boonton 4500B RF Peak Power Analyzer Operation 4-84 Table 4-31. Calibrator > Menu (continued) Menu Item Function (Type) Selectio

Página 65

Boonton 4500B RF Peak Power Analyzer Operation 4-85 Table 4-32. Calibrator > Pulse (Preset) > Submenu (continued) Menu Item Fun

Página 66

Boonton 4500B RF Peak Power Analyzer Operation 4-86 Table 4-33. Calibrator > Pulse (Variable) > Submenu Menu Item Function (Ty

Página 67

Boonton 4500B RF Peak Power Analyzer Operation 4-87 Figure 4-48. Table 4-34. Calibrator > Extensions > Submenu Menu

Página 68

Boonton 4500B RF Peak Power Analyzer Contents xvi Table 7-12. 59318 Sensor Frequency Calfactor Accuracy ... 7-22 Table 7-13. 563

Página 69

Boonton 4500B RF Peak Power Analyzer Operation 4-88 4.17 PRGM Key and Prgm > Menu The PRGM key activates the Prgm > menu (Figure 4-49), which

Página 70

Boonton 4500B RF Peak Power Analyzer Operation 4-89 Table 4-35. Prgm > Menu Menu Item Function (Type) Selections (SCPI C

Página 71

Boonton 4500B RF Peak Power Analyzer Operation 4-90 Table 4-36. Prgm > Inst Store > Menu Menu Item (Type) Selections

Página 72

Boonton 4500B RF Peak Power Analyzer Operation 4-91 Table 4-37. Prgm > Inst Store > Basename > Menu Menu Type (Type) Selections

Página 73 - 4. Operation

Boonton 4500B RF Peak Power Analyzer Operation 4-92 To recall a previously stored configuration, press the Prgm > Instr Recall menu key. A file sy

Página 74 - 4.3 Menu Conventions

Boonton 4500B RF Peak Power Analyzer Operation 4-93 Table 4-40. Prgm > Mem Save > Menu Menu Item Function (Type) Selec

Página 75

Boonton 4500B RF Peak Power Analyzer Operation 4-94 Table 4-41. Prgm > WFM Store > Menu Menu Item (Type) Selections Function Fol

Página 76 - 4.4 Data Entry Controls

Boonton 4500B RF Peak Power Analyzer Operation 4-95 Table 4-41. Prgm > WFM Store > Menu (continued) Menu Item Function (Type)

Página 77 - 4.5 Display Data

Boonton 4500B RF Peak Power Analyzer Operation 4-96 Table 4-42. Prgm > WFM Recall > Menu Menu Item Function (Type) Selections

Página 78

Boonton 4500B RF Peak Power Analyzer Operation 4-97 Table 4-43. Prgm > Trace Data > Menu Menu Item Function (Type) Selectio

Página 79 - 4.6 Top Level Menu

Boonton 4500B RF Peak Power Analyzer General Information 1-1 1. General Information This instruction manual provides you with the information you ne

Página 80

Boonton 4500B RF Peak Power Analyzer Operation 4-98 Table 4-43. Prgm > Trace Data > Menu (continued) Menu Item Function (Type)

Página 81

Boonton 4500B RF Peak Power Analyzer Operation 4-99 4.18 DISP Key and Disp > Menu The Display menu controls the way traces are drawn and how they

Página 82 - 4.7 System Keys

Boonton 4500B RF Peak Power Analyzer Operation 4-100 Filter setting. This results in a "peak hold" characteristic where the min and max pea

Página 83 - 4.8 Function Keys

Boonton 4500B RF Peak Power Analyzer Operation 4-101 Table 4-44. Display > Menu continued) Menu Item Function (Type) Selections

Página 84

Boonton 4500B RF Peak Power Analyzer Operation 4-102 Table 4-45. Display > Screen Saver > Submenu Menu Item Function (Type)

Página 85

Boonton 4500B RF Peak Power Analyzer Operation 4-103 Table 4-46. Display > Format > Submenu Menu Item Function (Type) Selecti

Página 86

Boonton 4500B RF Peak Power Analyzer Operation 4-104 Table 4-47. Display > Format > Trace Type (1 of 2 ) > Submenu Menu Item (Type) Se

Página 87

Boonton 4500B RF Peak Power Analyzer Operation 4-105 Table 4-48. Display > Format > Trace Type (2 of 2 ) > Submenu Menu Item F

Página 88

Boonton 4500B RF Peak Power Analyzer Operation 4-106 Table 4-49. Display > Format > Set Color > Submenu Menu Item Function

Página 89

Boonton 4500B RF Peak Power Analyzer Operation 4-107 Table 4-49. Display > Format > Set Color > Submenu (continued) Menu Item F

Página 90

Boonton 4500B RF Peak Power Analyzer General Information 1-2 1.2 Description The Model 4500B RF Peak Power Analyzer is the latest generation of BOONT

Página 91

Boonton 4500B RF Peak Power Analyzer Operation 4-108 4.19. SPCL Key and Spcl > Menu The SPCL key activates the Spcl > menu (Figure 4-65), which

Página 92

Boonton 4500B RF Peak Power Analyzer Operation 4-109 Table 4-51. Spcl >Trigger Out>Menu Menu Item (Type) Selections Function

Página 93

Boonton 4500B RF Peak Power Analyzer Operation 4-110 Table 4-52. Spcl > Servicing > Submenu Menu Item (Type) Selections Function

Página 94

Boonton 4500B RF Peak Power Analyzer Operation 4-111 Table 4-52. Spcl > Servicing > Submenu (continued) Menu Item (Type) Selections

Página 95

Boonton 4500B RF Peak Power Analyzer Operation 4-112 Table 4-53. Spcl > Servicing > Time Skew Adj > Submenu Menu Item Function

Página 96

Boonton 4500B RF Peak Power Analyzer Operation 4-113 Table 4-54. Spcl > Sensor Data > Submenu Menu Item (Type) Selections Function

Página 97

Boonton 4500B RF Peak Power Analyzer Operation 4-114 Table 4-55. Spcl > Sensor Data > CH 1,(2) Detail > Submenu Menu Type (Type) Select

Página 98

Boonton 4500B RF Peak Power Analyzer Operation 4-115 4.20 Automatic Operation The Model 4500B can make up to 15 automatic measurements. The available

Página 99

Boonton 4500B RF Peak Power Analyzer Operation 4-116 NOTE The Channel 1 and Channel 2 voltage readings are derived by converting power to equivalent

Página 100 - Operation

Boonton 4500B RF Peak Power Analyzer Operation 4-117 AUTOMATIC MEASUREMENTS – MODULATED MODE The Modulated mode is most often used to measure the tr

Página 101

Boonton 4500B RF Peak Power Analyzer General Information 1-3 1.3 Features . Software. splay, I/O a

Página 102

Boonton 4500B RF Peak Power Analyzer Operation 4-118 AUTOMATIC MEASUREMENTS – STATISTICAL MODE (Opt 10 only) In the Statistical mode automatic measu

Página 103

Boonton 4500B RF Peak Power Analyzer Operation 4-119 4.21 Model 4500B MENU MAP Table 4-63. Control Menu Structure

Página 104

Boonton 4500B RF Peak Power Analyzer Operation 4-120 Table 4-63. Control Chan 1/Chan 2 (pulse) Mem 1/Mem 2 (

Página 105

Boonton 4500B RF Peak Power Analyzer Operation 4-121 Menu Structure (continued) Ext Trig1/Ext Tri

Página 106

Boonton 4500B RF Peak Power Analyzer Operation 4-122 Table 4-63. Control Menu Structure (continued)

Página 107

Boonton 4500B RF Peak Power Analyzer Operation 4-123 Table 4-63. Control Menu Structure (continued) Mark

Página 108

Boonton 4500B RF Peak Power Analyzer Operation 4-124 Table 4-63. Control Menu Structure (continued)

Página 109

Boonton 4500B RF Peak Power Analyzer Operation 4-125 Table 4-63. Control Menu Structure (continued) Calibrator (pres

Página 110

Boonton 4500B RF Peak Power Analyzer Operation 4-126 Table 4-63. Control Menu Structure (continued)

Página 111

Boonton 4500B RF Peak Power Analyzer Operation 4-127 Table 4-63. Control Menu Structure (continued) Disp

Página 112

Boonton 4500B RF Peak Power Analyzer Contents ii INSTRUCTION MANUAL, MODEL 4500B RF PEAK POWER ANALYZER Revision date 7/13/2011 © C

Página 113

Boonton 4500B RF Peak Power Analyzer General Information 1-4 Color Display Waveforms, control menus, measurement values and related text are display

Página 114

Boonton 4500B RF Peak Power Analyzer Operation 4-128 (This Page Intentionally Blank)

Página 115

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-1 5. Remote Operation 5.1 GPIB CONFIGURATION The 4500B GPIB interface is configured using

Página 116

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-2 5.3 SCPI LANGUAGE All of the features of the Model 4500B are accessible with the SCPI comm

Página 117

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-3 SENSe3:RANGe? Query the range of external trigger channel TRIG1 SENS3:RANG? Query

Página 118

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-4 5.4 BASIC MEASUREMENT OPERATION. The easiest way to obtain a reading is by use of the MEA

Página 119

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-5 The Operation Status Register is read by the STATus:OPERation:CONDition? command. The transi

Página 120

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-6 5.5.1 IEEE 488.2 Commands The purpose of IEEE488.2 commands is to provide management and da

Página 121

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-7 *ESR? Description: Return the current value of the Standard Event Status Register, then

Página 122

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-8 *OPC Description: Clears the OPC (Operation Complete) status flag. This command is issue

Página 123

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-9 *SRE Description: Set or return the mask value in the Service Request Enable Register.

Página 124

Boonton 4500B RF Peak Power Analyzer General Information 1-5 1.4 Accessories Optional 4500B accessories that can be ordered from Boonton Electronics.

Página 125

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-10 *TRG Description: Simulate the bus trigger command.. This command has the same effect a

Página 126

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-11 5.5.2 CALCulate Subsystem The CALCulate group of the command subsystem is used to configur

Página 127

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-12 CALCulate:MATH:ARGA Description: Set or return the signal source of the A argument for

Página 128

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-13 CALCulate:PKHLD Description: 

Página 129

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-14 CALCulate:UNIT Description: Set or return units for the selected channel. For

Página 130

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-15 5.5.3 CALibration Subsystem The CALibration group of commands is used to control automatic

Página 131

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-16 CALibration:USER:FREQcal Description: Performs a single-point sensor gain calibrati

Página 132

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-17 5.5.4 DISPlay Subsystem The DISPlay group of commands is used to control the sel

Página 133

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-18 DISPlay:BRIGhtness:BLUE Description: Set or return the intensity of the blue co

Página 134

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-19 DISPlay:DECAdes Description: Set or return the number of decades displayed on

Página 135

Boonton 4500B RF Peak Power Analyzer General Information 1-6 1.5 Optional Configurations Basic. One measurement channel; the channel and trigger con

Página 136

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-20 DISPlay:HEADer Description: Set or return the type of header shown at the top left of

Página 137

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-21 DISPlay:PARAmeter:MODE Description: Set or return the type of content displayed in th

Página 138

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-22 DISPlay:CHANnel: MIDdle: LEFT Description: Set or return the channel for the auto-mea

Página 139

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-23 DISPlay:CHANnel:TOP: MIDdle Description: Set or return the channel for the auto-

Página 140

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-24 DISPlay:PARAmeter:BOTtom:RIGHt Description: Set or return the auto-measure or fixed par

Página 141

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-25 DISPlay:PARAmeter:MIDdle:RIGHt Description: Set or return the auto-measure or fixed par

Página 142

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-26 DISPlay:PARAmeter:TOP:RIGHt Description: Set or return the auto-measure or fixed parame

Página 143

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-27 DISPlay:PCTOFST Description: Set or return the horizontal trace percent offset of the s

Página 144

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-28 DISPlay:PLABel:TEXTA Description: Set or return line 1 of the plot label text up to 19

Página 145

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-29 DISPlay:PULSe:TIMEBASE Description: Set or return the pulse mode timebase in seconds/di

Página 146

Boonton 4500B RF Peak Power Analyzer General Information 1-7 Table 1-2 Model 4500B Performance Specifications (Specifications are subject to chan

Página 147

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-30 DISPlay:SKEW:REFerence Description: Set or return the reference channel for time skew

Página 148

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-31 DISPlay:TRACe:PDFBars Description: Set or return the number of bars in the PDF display

Página 149

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-32 DISPlay:TSPAN Description: Set or return the horizontal time span of the display. Time

Página 150

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-33 5.5.5 FETCh Queries The FETCh? group of queries is used to return specific measurement dat

Página 151

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-34 FETCh:ARRay:AMEAsure:TIMe? Description: Returns an array of the current automatic timin

Página 152

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-35 FETCh:ARRay:MARKer:POWer? Description: Returns an array of the current marker measureme

Página 153

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-36 FETCh:ARRay:TEMPerature:CALTemp? Description: Return the internal temperature of the Ch

Página 154

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-37 FETCh:INTERval:MAXimum? Description: For the specified channel, return the maximum inst

Página 155

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-38 FETCh:INTERval:PKAVG? Description: For the specified channel, return the peak-to-avera

Página 156

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-39 FETCh:MARKer:MAXimum? Description: For the specified channel and marker, return the ma

Página 157

Boonton 4500B RF Peak Power Analyzer General Information 1-8 Table 1-2 Model 4500B Performance Specifications (continued) (Specifications are subj

Página 158

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-40 FETCh:MARKer:RRATio? Description: For the specified channel return the ratio of MK2 to

Página 159

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-41 5.5.6 HCOPy Commands The HCOPy commands are used to control the printing of screen images

Página 160

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-42 5.5.7 INITiate and ABORt Commands The purpose of the INITiate group of commands is to sta

Página 161

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-43 INITiate[:IMMediate[:ALL]] Description: Starts a single measurement cycle when INIT

Página 162

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-44 5.5.8 MARKer Subsystem The MARKer group of commands is used to configure and locate measur

Página 163

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-45 MARKer:MATH:BOTH Description: Set the marker group to BOTH and configure the marker math

Página 164

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-46 MARKer:MATH:EACH Description: Set the marker group to EACH and configure the marker math

Página 165

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-47 MARKer:POSItion:PIXel Description: Set or return the horizontal pixel position (X-axis

Página 166

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-48 5.5.9 MEASure Queries The MEASure group of commands is used to acquire data using a set of

Página 167

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-49 5.5.10 MEMory Subsystem The MEMory group of commands is used to save and recall instrument

Página 168

Boonton 4500B RF Peak Power Analyzer General Information 1-9 Table 1-2 Model 4500B Performance Specifications (continued) (Specifications are subj

Página 169

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-50 MEMory:FREE? Description: Return the number of free bytes on the active drive.

Página 170

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-51 MEMory:SNSR:INFO? Description: Return the sensor ID and parameter data. Syntax: MEM

Página 171

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-52 MEMory:SYS:STORe Description:       

Página 172

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-53 MMEMory:SAVE:DISPlay Description: 

Página 173

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-54 5.5.11 OUTPut Subsystem The OUTPut group of commands is used to control the internal 1GHz

Página 174

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-55 OUTPut:MODUlation Description: Set or return the output modulation state for the 1 GHz

Página 175

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-56 OUTPut:PULse:PERiod Description: Set or return the pulse period in the Preset pulse con

Página 176

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-57 OUTPut:TRIGout[1/2]:SOURce Description: Set or return the signal type for the measureme

Página 177

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-58 5.5.12 READ Queries The purpose of the READ? group of queries is to initiate a measurement

Página 178

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-59 READ:ARRay:AMEAsure:TIMe? Description: Returns an array of the current automatic timing

Página 179

Boonton 4500B RF Peak Power Analyzer General Information 1-10 Table 1-2 Model 4500B Performance Specifications (continued) (Specifications are sub

Página 180

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-60 READ:ARRay:MARKer:POWer? Description: Returns an array of the current marker measureme

Página 181

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-61 READ:INTERval:MAXimum? Description: For the specified channel, return the maximum inst

Página 182

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-62 READ:INTERval:PKAVG? Description: For the specified channel, return the peak-to-averag

Página 183

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-63 READ:MARKer:MINimum? Description: For the specified channel and marker, return the min

Página 184

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-64 5.5.13 REFLine Subsystem The REFLine group of commands is used to configure and locate ho

Página 185

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-65 REFLine:TRACk Description: Controls the automatic tracking of waveform parameters using

Página 186

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-66 5.5.14 SENSe Subsystem The purpose of the SENSe command subsystem is to directly configur

Página 187 - 4.20 Automatic Operation

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-67 5.5.14.1 SENSe:CALTAB Data Array Commands The purpose of the SENS:CALTAB gro

Página 188

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-68 SENSe:CORRection:FDOFfset Description: Set or return the name of the current freq

Página 189

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-69 SENSe:CORRection:OFFSet Description: Set or return a measurement offset in dB for the s

Página 190

Boonton 4500B RF Peak Power Analyzer General Information 1-11 Table 1-2 Model 4500B Performance Specifications (continued) (Specifications are sub

Página 191 - 4.21 Model 4500B MENU MAP

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-70 SENSe:FILTer:TIMe Description: Set or return the current length of the integration filt

Página 192

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-71 5.5.14.2 SENSe:HISTogram Data Array Commands The purpose of the SENS:HISTogram group of c

Página 193

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-72 SENSe:IMPedance Description: Set or return trigger channel impedance for the se

Página 194

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-73 SENSe:PULSe:MESIal Description: Set or return the pulse amplitude percentage, which is

Página 195

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-74 SENSe:PULSe:UNIT Description: Set or return the units for entering the pulse distal, m

Página 196

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-75 5.5.15 STATus Commands The STATus command subsystem enables you to control the SC

Página 197

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-76 STATus:OPERation:EVENt? Description: This query returns the contents of the Operation E

Página 198

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-77 STATus:QUEStionable:CONDition? Description: Return the current value (condition) of the

Página 199

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-78 STATus:QUEStionable:NTRansition Description: Sets the negative transition filter. Setting

Página 200

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-79 (This Page Intentionally Blank)

Página 201 - 5. Remote Operation

Boonton 4500B RF Peak Power Analyzer General Information 1-12 Table 1-2 Model 4500B Performance Specifications (continued) (Specifications are sub

Página 202 - Remote Operation

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-80 5.5.16 SYSTem Subsystem The SYSTem group of commands is used to control system-level funct

Página 203

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-81 SYSTem:COMMunicate:GPIB:LISTen Description: Set or return the 4500B as LISTENER line te

Página 204

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-82 SYSTem:COMMunicate:SERial:BITS Description: Set or return the number of serial bits per

Página 205 - 5.5 SCPI COMMAND REFERENCE

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-83 SYSTem:DATE:DAY Description: Set or return the day of the month of the real time clock.

Página 206

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-84 SYSTem:ERRor[:NEXT]? Description: Returns the next queued error code number followed by

Página 207

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-85 SYSTem:PRESet Description: Set 4500B default parameters. Equivalent to pressing the fro

Página 208

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-86 5.5.17 TRACe Data Array Commands The TRACe group of commands is used to control the output

Página 209

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-87 TRACe:DELImiter Description: Set or return the ASCII data delimiter used to separate

Página 210

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-88 TRACe:INDEX Description: Set or return the array index for the first trace point to be

Página 211

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-89 TRACe:SEND Description: Send the trace data for the source selected by TRACe:S

Página 212

Boonton 4500B RF Peak Power Analyzer Installation 2-1 2. Installation This section contains unpacking and repacking instructions, power requirements

Página 213

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-90 5.5.18 TRIGger Subsystem The TRIGger group of commands is used to control synchronization

Página 214

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-91 TRIGger:BTRIGger:SLOPe Description: Set or return the B trigger slope or polarity. Whe

Página 215

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-92 TRIGger:CDF:COUNt Description: Set or return the terminal count (sample population si

Página 216

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-93 TRIGger:DELay Description: Set or return the trigger delay time in seconds with respect

Página 217

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-94 TRIGger:LEVel Description: Set or return the trigger level for synchronizing data acq

Página 218

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-95 TRIGger:POSition Description: Set or return the position of the trigger event on displa

Página 219

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-96 TRIGger:STATistical:GATE Description: Set or return the marker locations in time relati

Página 220

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-97 (This Page Intentionally Blank)

Página 221

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-98 Table 5-1. SCPI COMMAND SUMMARY *OPT Return the instrument options *CLS Clear Stat

Página 222

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-99 Table 5-1. SCPI COMMAND SUMMARY (continued) CALCulate[1|2|5|6|7]:UNIT Chan

Página 223

Boonton 4500B RF Peak Power Analyzer Contents iii SAFETY SUMMARY The following general safety precautions must be observed during all phases of oper

Página 224

Boonton 4500B RF Peak Power Analyzer Installation 2-2 Table 2-1 Model 4500B Packing List INSTRUMENT (See also Table 1-1) Model 4500B RF Peak Power A

Página 225

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-100 Table 5-1. SCPI COMMAND SUMMARY (continued) DISPlay:PARAmeter:MIDdle:LEFT Ass

Página 226

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-101 Table 5-1. SCPI COMMAND SUMMARY (continued) DISPlay:TRACe:MKCENTer Ch

Página 227

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-102 Table 5-1. SCPI COMMAND SUMMARY (continued) FETCh[1|2|6|7]:INTERval:PKAVG? Retu

Página 228

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-103 Table 5-1. SCPI COMMAND SUMMARY (continued) MEASure[1|2]:POWer? Return modulated mod

Página 229

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-104 Table 5-1. SCPI COMMAND SUMMARY (continued) OUTPut:PULSe:CTRL Set/return

Página 230

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-105 Table 5-1. SCPI COMMAND SUMMARY (continued) READ[1|2|3|4|5|6|7]:MARKer:RATio? R

Página 231

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-106 Table 5-1. SCPI COMMAND SUMMARY (continued) SENSe[3|4]:IMPedance

Página 232

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-107 Table 5-1. SCPI COMMAND SUMMARY (continued) SYSTem:COMMunicate:GPIB:LISTen Set

Página 233

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-108 Table 5-1. SCPI COMMAND SUMMARY (continued) TRIGger:BTRIGger:MODE Select B trigg

Página 234

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-109 Table 5-2. 4400/4500/4400A/4500A EMULATION COMMANDS Supported Commands

Página 235

Boonton 4500B RF Peak Power Analyzer Installation 2-3 Note If the sensor connector is not a type N, install the appropriate adapter (from the

Página 236

Boonton 4500B RF Peak Power Analyzer Remote Operation 5-110 Table 5-2. 4400/4500/4400A/4500A EMULATION COMMANDS (continued) Ignored Co

Página 237

Boonton 4500B RF Peak Power Analyzer Application Notes 6-1 6. Application Notes This section provides supplementary material to enhance your knowled

Página 238

Boonton 4500B RF Peak Power Analyzer Application Notes 6-2 Figure 6-1. Pulsed RF Signal Figure 6-2. Distorted Pulse Signal

Página 239

Boonton 4500B RF Peak Power Analyzer Application Notes 6-3 Diode Detection Wideband diode detectors are the dominant power sensing device used to me

Página 240

Boonton 4500B RF Peak Power Analyzer Application Notes 6-4 Frequency Response. The carrier frequency response of a diode detector is determined mostly

Página 241

Boonton 4500B RF Peak Power Analyzer Application Notes 6-5 6.2 Pulse Definitions -

Página 242

Boonton 4500B RF Peak Power Analyzer Application Notes 6-6 Table 6-1. Pulse Terms TERM DEFINITION Base Line The two portions of a pulse

Página 243

Boonton 4500B RF Peak Power Analyzer Application Notes 6-7 Automatic Measurement Terms The following terms appear in the Model 4500B Text display in

Página 244

Boonton 4500B RF Peak Power Analyzer Application Notes 6-8 Automatic Measurement Sequence The automatic measurement process analyzes the captured si

Página 245

Boonton 4500B RF Peak Power Analyzer Application Notes 6-9 7. The process locates the bottom amplitude (baseline) using the IEEE histogram method. A

Página 246

Boonton 4500B RF Peak Power Analyzer Installation 2-4 7. Ve

Página 247

Boonton 4500B RF Peak Power Analyzer Application Notes 6-10 Item dBm mW Mesial value 10.0 10.0 Sample n 8.0

Página 248

Boonton 4500B RF Peak Power Analyzer Application Notes 6-11 12. The processor calculates the output values according to the following definitions:

Página 249

Boonton 4500B RF Peak Power Analyzer Application Notes 6-12 Figure 6-7 Sampling Intervals 14. The processor calculates the delay be

Página 250

Boonton 4500B RF Peak Power Analyzer Application Notes 6-13 6.4 Statistical Mode Automatic Measurements (Model 4500B Opt 10 only) When operating in S

Página 251

Boonton 4500B RF Peak Power Analyzer Application Notes 6-14 Table 6-3. Statistical Automatic Measurements (Opt 10 only) In the Statistical mode the f

Página 252

Boonton 4500B RF Peak Power Analyzer Application Notes 6-15 The following two global status values are displayed: Text TERM

Página 253

Boonton 4500B RF Peak Power Analyzer Application Notes 6-16 6.5 Measurement Accuracy The Model 4500B includes a precision, internal, 1 GHz RF referen

Página 254

Boonton 4500B RF Peak Power Analyzer Application Notes 6-17 The worst case approach is a very conservative method in which the extreme conditions of e

Página 255

Boonton 4500B RF Peak Power Analyzer Application Notes 6-18 The value to use for calibration level uncertainty depends upon the sensor calibration tec

Página 256

Boonton 4500B RF Peak Power Analyzer Application Notes 6-19 Sensor Temperature Coefficient. This term is the e

Página 257

Boonton 4500B RF Peak Power Analyzer Installation 2-5 9. Verify that the Instrument Serial Number matches the number on the label at the top center o

Página 258

Boonton 4500B RF Peak Power Analyzer Application Notes 6-20 The sensor calfactor uncertainty is due to uncertainties encountered while performing this

Página 259

Boonton 4500B RF Peak Power Analyzer Application Notes 6-21 Step 3: The Calibrator Mismatch Uncertainty is calculated using the formula in the previ

Página 260

Boonton 4500B RF Peak Power Analyzer Application Notes 6-22 Step 9: The Sensor Calfactor Uncertainty needs to be interpolated from the uncertainty va

Página 261

Boonton 4500B RF Peak Power Analyzer Maintenance 7-1 7. Maintenance This section presents procedures for maintaining the Model 4500B. 7.1 Safety

Página 262

Boonton 4500B RF Peak Power Analyzer Maintenance 7-2 7.5 Software Upgrade Instrument operating software has been loaded into the Model 4500B at the f

Página 263

Boonton 4500B RF Peak Power Analyzer Maintenance 7-3 7.6 Test Equipment Table 7-1 lists the equipment required to test and calibrate the Model 4500B.

Página 264

Boonton 4500B RF Peak Power Analyzer Maintenance 7-4 7.7 Performance Verification The verification procedure demonstrates that the Model 4500B is pe

Página 265

Boonton 4500B RF Peak Power Analyzer Maintenance 7-5 Calibrator Frequency Verification Before performing the calibrator frequency and linearity verif

Página 266

Boonton 4500B RF Peak Power Analyzer Maintenance 7-6 9. Remove the 15 dB attenuator and connect the HP8481A sensor directly to the Model 4500B 1 GHz

Página 267

Boonton 4500B RF Peak Power Analyzer Maintenance 7-7 8. Set the 4500B calibrator to 0 dBm (CW) by selecting Calibrator > Set Level > 0.0 dBm,

Página 268

Boonton 4500B RF Peak Power Analyzer Installation 2-6 (This Page Intentionally Blank)

Página 269

Boonton 4500B RF Peak Power Analyzer Maintenance 7-8 Pulse Mode. To verify sensor linearity in the pulse measurement mode, proceed as follows:

Página 270

Boonton 4500B RF Peak Power Analyzer Maintenance 7-9 4. Select one of the following tables (Tables 7-8 through 7-10) according to the sensor type be

Página 271

Boonton 4500B RF Peak Power Analyzer Maintenance 7-10 12. For Type N sensors, connect the K-Connector® to-N adapter and the 44-6 6-dB attenuator to

Página 272

Boonton 4500B RF Peak Power Analyzer Maintenance 7-11 Sensor Risetime Verification The risetime test uses the internal calibrator and the autom

Página 273

Boonton 4500B RF Peak Power Analyzer Maintenance 7-12 Calibrator External Pulse Verification Verify the external pulse input for the calibrat

Página 274

Boonton 4500B RF Peak Power Analyzer Maintenance 7-13 GPIB (IEEE-488) Bus Verification Use the GPIB Controller and the Model 4500B to perform

Página 275

Boonton 4500B RF Peak Power Analyzer Maintenance 7-14 7.8 1GHz Calibrator Output Level Calibration Calibrator 0 dBm Setting Use the following

Página 276

Boonton 4500B RF Peak Power Analyzer Maintenance 7-15 Table 7-2. 4500B Verification Checklist Check fuse type and rating: 3AG,250 volt, 1.6 amp

Página 277

Boonton 4500B RF Peak Power Analyzer Maintenance 7-16 Table 7-3a. Calibrator Linearity - High Power Range Cal Level Minimum

Página 278

Boonton 4500B RF Peak Power Analyzer Maintenance 7-17 Table 7-4. Sensor VSWR/Return Loss Sensor Model(s) Freq Range (GHz) VSWR Return Loss (dB) Me

Página 279

Boonton 4500B RF Peak Power Analyzer Getting Started 3-1 3. Getting Started This chapter will introduce the user to the Model 4500B. The chapter wil

Página 280

Boonton 4500B RF Peak Power Analyzer Maintenance 7-18 Table 7-5. 56218/318/326/340, 57318/340, 59318/340 Sensor Linearity (Pulse)

Página 281

Boonton 4500B RF Peak Power Analyzer Maintenance 7-19 Table 7-7. 57006 Sensor Linearity (Pulse)

Página 282

Boonton 4500B RF Peak Power Analyzer Maintenance 7-20 Table 7-9. 56518/526/540, 57518/540 Sensor Linearity (CW)

Página 283

Boonton 4500B RF Peak Power Analyzer Maintenance 7-21 Table 7-10. 57006 Sensor Linearity (CW)

Página 284

Boonton 4500B RF Peak Power Analyzer Maintenance 7-22 Table 7-12. 59318 Sensor Frequency Calfactor Accuracy

Página 285

Boonton 4500B RF Peak Power Analyzer Maintenance 7-23 Table 7-14. 56340/540, 57340/540, 59340 Sensor Frequency Calfactor Accuracy

Página 286

Boonton 4500B RF Peak Power Analyzer Maintenance 7-24 Table 7-15. Sensor Risetime Sensor Model(s) Test Level (dBm) Min High BW Measured Max Min

Página 287

Boonton 4500B RF Peak Power Analyzer Maintenance 7-25 Table 7-15 (continued). Sensor Risetime Sensor Model(s) Test Level (dBm) Min High BW Measured

Página 288

Boonton 4500B RF Peak Power Analyzer Maintenance 7-26 (This Page Intentionally Blank)

Página 289

Boonton 4500B RF Peak Power Analyzer Appendix A 8-1 8. Appendix A SCPI Error Messages NO. MESSAGE DESCRIPTION -100 "Command E

Página 290

Boonton 4500B RF Peak Power Analyzer Getting Started 3-2 Figure 3-1. Standard Model 4500B RF Peak Power Analyzer - Front Panel

Página 291

Boonton 4500B RF Peak Power Analyzer Appendix A 8-2 NO. MESSAGE DESCRIPTION -249 "FPGA download err" -256 "Error file n

Página 292

Boonton 4500B RF Peak Power Analyzer Appendix A 8-3 NO. MESSAGE DESCRIPTION -375 "Cmd not accepted" -376 "I2C Timeout&q

Página 293

Boonton 4500B RF Peak Power Analyzer Appendix A 8-4 (This Page Intentionally Blank)

Página 294

Boonton 4500B RF Peak Power Analyzer Appendix B 9-1 9. Appendix B Microsoft® Windows® XP Professional END-USER LICENSE AGREEMENT IMPORTANT-READ C

Página 295

Boonton 4500B RF Peak Power Analyzer Appendix B 9-2 2. UPGRADES. To use a Product identified as an upgrade, you must first be licensed

Página 296

Boonton 4500B RF Peak Power Analyzer Appendix B 9-3 * Internet-Based Services Components. The Product contains components that enable and facilitate

Página 297

Boonton 4500B RF Peak Power Analyzer Appendix B 9-4 YOUR EXCLUSIVE REMEDY. Microsoft's and its suppliers' entire liability and your exclusi

Página 298

Boonton 4500B RF Peak Power Analyzer Appendix B 9-5 15. LIMITATION OF LIABILITY AND REMEDIES. Notwithstanding any damages that you might incur for a

Página 299

Boonton 4500B RF Peak Power Analyzer Appendix B 9-6 (This page intentionally blank)

Página 300

Boonton 4500B RF Peak Power Analyzer Appendix B 9-7 "Boonton Electronics Model 4500B Operating Software" END-USER LICENSE AGREEMENT IMPOR

Página 301

Boonton 4500B RF Peak Power Analyzer Getting Started 3-3 Figure 3-1a. Model 4500B - Front Panel – System and Function keys

Página 302

Boonton 4500B RF Peak Power Analyzer Appendix B 9-8 8. U.S. GOVERNMENT LICENSE RIGHTS. All Product provided to the U.S. Government pursuan

Página 303

Boonton 4500B RF Peak Power Analyzer Appendix C 10-1 10. Appendix C Repair Policy Model 4500B Instrument. If the Boonton Model 4500B RF Peak Power

Página 304

Boonton 4500B RF Peak Power Analyzer Appendix C 10-2 Limited Warranty Boonton Electronics warrants its products to the original Purchaser to be fre

Página 305

Boonton 4500B RF Peak Power Analyzer Getting Started 3-4 Table 3-1 Operating Controls, Indicators and Connections (continued) Ref. No. Front Rear

Página 306

Boonton 4500B RF Peak Power Analyzer Getting Started 3-5 Figure 3-1b. Model 4500B - Front Panel – System and Func

Página 307

Boonton 4500B RF Peak Power Analyzer Contents iv SAFETY SYMBOLS This safety requirement symbol (located on the rear panel) has been adopted by the In

Página 308

Boonton 4500B RF Peak Power Analyzer Getting Started 3-6 Table 3-1 Operating Controls, Indicators and Connections (continued) Ref. No. Front Rear

Página 309

Boonton 4500B RF Peak Power Analyzer Getting Started 3-7 Table 3-1 Operating Controls, Indicators and Connections (continued) Ref. No. Front Rear

Página 310

Boonton 4500B RF Peak Power Analyzer Getting Started 3-8 Figure 3-2a. Model 4500B - Rear Panel I/O connectors Table 3-1

Página 311 - 6. Application Notes

Boonton 4500B RF Peak Power Analyzer Getting Started 3-9 Table 3-1 Operating Controls, Indicators and Connections (continued) Ref. No. Front Rear

Página 312 - Application Notes

Boonton 4500B RF Peak Power Analyzer Getting Started 3-10 Figure 3-3a. LCD Monitor Graphic Display Table 3-2 LCD Moni

Página 313

Boonton 4500B RF Peak Power Analyzer Getting Started 3-11 Table 3-2 LCD Monitor Display Fields (continued) Ref. No. Field Name Description

Página 314

Boonton 4500B RF Peak Power Analyzer Getting Started 3-12 Figure 3-3b. LCD Monitor Text Display 3.4 Initialize The

Página 315 - 6.2 Pulse Definitions

Boonton 4500B RF Peak Power Analyzer Getting Started 3-13 Caution When selecting a sensor for an exercise or a measurement, be sure you know the powe

Página 316 - 6.3 Automatic Measurements

Boonton 4500B RF Peak Power Analyzer Getting Started 3-14 Table 3-3. Initialized Parameters Parameter Applies to: Default Graph/Text/H

Página 317

Boonton 4500B RF Peak Power Analyzer Getting Started 3-15 Table 3-3. Initialized Parameters (continued) Parameter Applies to: Default

Página 318

Boonton 4500B RF Peak Power Analyzer Contents v Contents 1. General Information ...

Página 319

Boonton 4500B RF Peak Power Analyzer Getting Started 3-16 Table 3-3. Initialized Parameters (continued) Parameter Applies to: Default

Página 320

Boonton 4500B RF Peak Power Analyzer Getting Started 3-17 Table 3-3. Initialized Parameters (continued) Parameter Applies to: Default

Página 321

Boonton 4500B RF Peak Power Analyzer Getting Started 3-18 3.5 Calibration Before any measurements can be acquired with the Model 4500B, a sensor must

Página 322

Boonton 4500B RF Peak Power Analyzer Getting Started 3-19 STEP PROCEDURE 8. Press the Chan 1 > Calibration > AutoCal menu key to init

Página 323

Boonton 4500B RF Peak Power Analyzer Getting Started 3-20 This completes the Calibration 

Página 324

Boonton 4500B RF Peak Power Analyzer Getting Started 3-21 MENU ITEM EXERCISE CHAN (continued) Chan 1 > Vert Scale If the Chan 1 > Vert S

Página 325

Boonton 4500B RF Peak Power Analyzer Getting Started 3-22 MENU ITEM EXERCISE CHAN (continued) Chan 1 > Exten Press the Chan 1 > Exten

Página 326 - 6.5 Measurement Accuracy

Boonton 4500B RF Peak Power Analyzer Getting Started 3-23 MENU ITEM EXERCISE CHAN (continued) Chan 1 > Exten Press the Chan 1 > Extens

Página 327

Boonton 4500B RF Peak Power Analyzer Getting Started 3-24 Figure 3-8. Trig > Menu MENU ITEM EXERCISE TRI

Página 328

Boonton 4500B RF Peak Power Analyzer Getting Started 3-25 MENU ITEM EXERCISE TRIG (continued) Trig > Trig Mode Press the Trig > Trig Mo

Página 329

Boonton 4500B RF Peak Power Analyzer Contents vi 3.3 LCD Monitor Display ...

Página 330

Boonton 4500B RF Peak Power Analyzer Getting Started 3-26 MENU ITEM EXERCISE TRIG (continued) Trig > HoldOff This effect of this control ca

Página 331

Boonton 4500B RF Peak Power Analyzer Getting Started 3-27 Figure 3-9. Mark > Exten Menu MENU ITEM EXERCISE ME

Página 332

Boonton 4500B RF Peak Power Analyzer Getting Started 3-28 MENU ITEM EXERCISE MEAS (continued) Meas > Freq CH1 Use any of the data entry con

Página 333 - 7. Maintenance

Boonton 4500B RF Peak Power Analyzer Getting Started 3-29 3.7 Practice Exercise for Statistical Power Measurements (4500B Opt 10 only) In the followi

Página 334 - 7.5 Software Upgrade

Boonton 4500B RF Peak Power Analyzer Getting Started 3-30 Figure 3-14. CCDF > Statistics Menu MENU ITEM EXERCIS

Página 335 - 7.6 Test Equipment

Boonton 4500B RF Peak Power Analyzer Getting Started 3-31 MENU ITEM EXERCISE Top Level (continued) Ref 1, R Delta and Ref 2 - Thes

Página 336 - 7.7 Performance Verification

Boonton 4500B RF Peak Power Analyzer Getting Started 3-32 MENU ITEM EXERCISE CHAN (continued) Chan 1 > Vert Center Press the Chan 1 > V

Página 337

Boonton 4500B RF Peak Power Analyzer Getting Started 3-33 MENU ITEM EXERCISE CHAN (continued) Chan 1 > Exten Press the Chan 1 > Extens

Página 338

Boonton 4500B RF Peak Power Analyzer Getting Started 3-34 MENU ITEM EXERCISE TIME (continued) Time (Statistics) Press the Time (Statistics)

Página 339

Boonton 4500B RF Peak Power Analyzer Getting Started 3-35 MENU ITEM EXERCISE TIME (continued) Time (Statistics) Press the Time (Statistics)

Página 340

Boonton 4500B RF Peak Power Analyzer Contents vii Table 4-14. Meas > Menu (pulse and modulated) ... 4-61 Table 4-

Página 341

Boonton 4500B RF Peak Power Analyzer Getting Started 3-36 MENU ITEM EXERCISE MEAS (continued) Meas > Freq CH2 Frequency entry for Channel

Página 342

Boonton 4500B RF Peak Power Analyzer Getting Started 3-37 MENU ITEM EXERCISE TRIG (continued) Trig (Statistical) Press the Trig > Gate 1

Página 343

Boonton 4500B RF Peak Power Analyzer Getting Started 3-38 (This Page Intentionally Blank)

Página 344

Boonton 4500B RF Peak Power Analyzer Operation 4-1 4. Operation This section presents the control menus and procedures for operating the Model 4500

Página 345

Boonton 4500B RF Peak Power Analyzer Operation 4-2 4.2 Manual Operation In the manual mode, the instrument is controlled from the front panel by sele

Página 346

Boonton 4500B RF Peak Power Analyzer Operation 4-3 6. A Numerical Value in a menu entry box represents the current value of that parameter. See the C

Página 347

Boonton 4500B RF Peak Power Analyzer Operation 4-4 4.4 Data Entry Controls The numeric keypad illustrated in Figure 4-6 is one of the three data entr

Página 348

Boonton 4500B RF Peak Power Analyzer Operation 4-5 The units keys labeled G, M, and k are used to enter frequencies in Gigahertz, Megahertz, and kiloh

Página 349

Boonton 4500B RF Peak Power Analyzer Operation 4-6 The message priority from highest to lowest is: Highest Measuring Stopped!! No measurements

Página 350

Boonton 4500B RF Peak Power Analyzer Operation 4-7 4.6 Top Level Menu The commands in the Top Level Menu (Figure 4-7) enable you to control the measu

Página 351

Boonton 4500B RF Peak Power Analyzer Contents viii Table 4-50. Spcl > Menu ...

Página 352

Boonton 4500B RF Peak Power Analyzer Operation 4-8 Table 4-1. Top Level Menu (continued) Menu Item Function (Type) Selection

Página 353

Boonton 4500B RF Peak Power Analyzer Operation 4-9 Table 4-1. Top Level Menu (continued) Menu Item Function (Type) Selectio

Página 354

Boonton 4500B RF Peak Power Analyzer Operation 4-10 Figure 4-8. System Keys 4.7 System Keys The system keys are located at the t

Página 355

Boonton 4500B RF Peak Power Analyzer Operation 4-11 Print Pressing the Print key will cause the screen image to be captured to memory and the Print

Página 356

Boonton 4500B RF Peak Power Analyzer Operation 4-12 4.9 CHAN Key and Chan # > Menu The CHAN key activates the Chan # > menu and associated subm

Página 357

Boonton 4500B RF Peak Power Analyzer Operation 4-13 Figures and Tables The figures and tables which describe the Chan # > family of menus are s

Página 358

Boonton 4500B RF Peak Power Analyzer Operation 4-14 Table 4-2. Chan # > Menu (continued) Menu Item Function (Type) Selec

Página 359 - 8. Appendix A

Boonton 4500B RF Peak Power Analyzer Operation 4-15 Table 4-2. Chan # > Menu (continued) Menu Item Function (Type) Sele

Página 360 - Appendix A

Boonton 4500B RF Peak Power Analyzer Operation 4-16 Calibration A discussion of the internal calibration capability is presented in Subsection 4

Página 361

Boonton 4500B RF Peak Power Analyzer Operation 4-17 Table 4-3. Chan # > Calibration > Submenu (continued) Menu Item Function

Página 362

Boonton 4500B RF Peak Power Analyzer Contents ix CALCulate:AMEAsure:MODE ... 5-1

Página 363 - 9. Appendix B

Boonton 4500B RF Peak Power Analyzer Operation 4-18 Table 4-3. Chan # > Calibration > Submenu (continued) Menu Item Function

Página 364 - Appendix B

Boonton 4500B RF Peak Power Analyzer Operation 4-19 Table 4-4. Chan # > Extensions > Submenu Menu Item Function (Type)

Página 365

Boonton 4500B RF Peak Power Analyzer Operation 4-20 Table 4-4. Chan # > Extensions > Submenu (continued) Menu Item Function

Página 366

Boonton 4500B RF Peak Power Analyzer Operation 4-21 Table 4-4A. Chan # > Extensions > Corrections > Submenu Menu Item Function

Página 367

Boonton 4500B RF Peak Power Analyzer Operation 4-22 Table 4-4A. Chan # > Extensions > Corrections > Submenu (continued) Menu Item

Página 368

Boonton 4500B RF Peak Power Analyzer Operation 4-23 Table 4-4B. Chan # > Extensions > Define Pulse > Submenu (continued) Menu Item

Página 369 - END-USER LICENSE AGREEMENT

Boonton 4500B RF Peak Power Analyzer Operation 4-24 Table 4-4B. Chan # > Extensions > Define Pulse > Submenu (continued) Menu Item

Página 370

Boonton 4500B RF Peak Power Analyzer Operation 4-25 Figure 4-17a. Sum of Channel 1 and Channel 2 power. Markers

Página 371 - 10. Appendix C

Boonton 4500B RF Peak Power Analyzer Operation 4-26 Channel Math The Channel Math function calculates and displays the sum, difference, ratio or pro

Página 372 - Limited Warranty

Boonton 4500B RF Peak Power Analyzer Operation 4-27 Table 4-6. Chan Math > Expression > Submenu Menu Item Function (Type)

Comentários a estes Manuais

Sem comentários